更新時間:2025-10-12
訪問量:759
廠商性質(zhì):代理商
生產(chǎn)地址:

參數(shù)  | 分辨率  | 精度  | 范圍  | 說明  | 
煙道溫度  | 0.01oC  | 0.01℃±0.3%讀數(shù)  | 0-1200oC  | >600℃用高溫探針  | 
環(huán)境溫度  | 0.01oC  | 0.01℃±0.3%讀數(shù)  | -50℃~50℃  | |
壓力  | 1pa  | ±2.0% 讀數(shù)  | ±15000pa  | 過量程±25000pa  | 
氣體測量  | ||||
O2  | 0.01%  | ±0.2% 讀數(shù)  | 0-25%  | 除O2外(O2為必測項目),用戶可根據(jù)需要在 SO2、NO、NO2、CO 四種傳感器中任選1-3 個。測量范圍也可選擇,但不可以同時選擇兩個濃度的同一傳感器。  | 
CO  | 1ppm  | ±5% 讀數(shù)  | 0-10,000ppm  | |
NO(標準量程)  | 1ppm  | ±5% 讀數(shù)  | 0-5000ppm  | |
NO(低量程)  | 1ppm  | ±5% 讀數(shù)  | 0-200ppm  | |
NO2  | 1 ppm  | ±5% 讀數(shù)  | 0-1000ppm  | |
SO2(標準量程)  | 1ppm  | ±5% 讀數(shù)  | 0-5000ppm  | |
SO2(低量程)  | 1ppm  | ±5% 讀數(shù)  | 0-200ppm  | |
自動計算  | ||||
CO2  | 0.1%  | ±0.3% 讀數(shù)  | 0-99.9%  | |
NOx  | 1ppm  | ±5% 讀數(shù)  | 0-6000ppm  | |
損失  | 0.1%  | ±1.0% 讀數(shù)  | 0-99.9%  | |
燃燒效率  | 0.1%  | ±1.0% 讀數(shù)  | 0-99.9%  | |
過剩空氣系數(shù)  | 0.1%  | ±0.2%  | 0-2885.0%  | |
凈溫度  | 0.01oC  | 0.01℃±0.3% 讀數(shù)  | 0-1200oC  | |
煙氣流速  | ±0.1m/s  | ±2.2% 讀數(shù)  | 2-45 m/s  | 根據(jù)煙道壓力和溫度計算  | 
尺寸  | 220mm ×55mm ×120mm  | |||
重量  | 1kg  | |||
電源  | 交直流兩用220V 50Hz或DC12V  | |||
內(nèi)置充電電池  | 滿充電后連續(xù)使用6小時  | |||
標準配置  | 主機、350mm長探針、塵水過濾器、充電器、便攜包、說明書  | |||